To view/change Dialogic Parameters, select CALLMaster Manager | Parameters | Dialogic.
Dialogic Parameters 58 thru 76
Parameter: | PAUSE_TIME |
Description: | Dialing pause duration in 1/100 seconds. |
Default: | 200 |
Range: | 1-999 units (10ms per unit) |
Usage: | Delay caused by a comma (,) in the dialing string. |
Parameter: | DIGRATE |
Description: | Digitizing rate in Hertz |
Default: | 6000 |
Range: | 6000/8000 Hertz |
Usage: | Default play/record digitization rate for the dialogic native format VOX files. (Not used). |
Parameter: | P_BK |
Description: | Pulse dialing break interval in 1/100 seconds. |
Default: | 6 |
Range: | 1-99 |
Usage: | Duration of the pulse dial off-hook interval. |
Parameter: | P_MK |
Description: | Pulse dialing make interval in 1/100 seconds |
Default: | 4 |
Range: | 1-99 |
Usage: | Duration of the pulse dial on-hook interval. |
Parameter: | P_IDD |
Description: | Pulse dialing inter-digit delay in 1/100 seconds. |
Default: | 100 |
Range: | 1-999 |
Usage: | Delay between digits during pulse dialing. |
Parameter: | T_IDD |
Description: | Tone dialing inter-digit delay in 1/100 seconds. |
Default: | 5 |
Range: | 1-999 |
Usage: | Delay between digits during DTMF dialing. |
Parameter: | OH_DLY |
Description: | Off-hook delay interval in 1/100 seconds. |
Default: | 50 |
Range: | 1-99 units (10ms per unit) |
Usage: | Time delay that occurs after executing a channel off-hook command. DTMF digits are not recognized while going off-hook. If your application requires immediate DTMF, wink, or loop current drop detection upon going off-hook, set the OH_DLY to 1. |
Parameter: | R_ON |
Description: | Ringing ON interval for ring-detect in 1/10 seconds. |
Default: | 2 |
Range: | 1-99 |
Usage: | Minimum ring voltage on duration for an incoming ring. |
Parameter: | R_OFF |
Description: | Ringing Off interval for ring-detect |
Default: | 5 |
Range: | 1-99 |
Usage: | Minimum ring voltage off duration for an incoming ring. |
Parameter: | R_IRD |
Description: | Delay for ring count reset in 1/10 seconds. |
Default: | 80 |
Range: | 1-99 |
Usage: | Maximum time between incoming rings. The ring counter is reset after this time has expired; rings that occur after this interval are considered the start of a new call cycle. |
Parameter: | S_BNC |
Description: | Silence message debounce interval in 1/100 seconds. |
Default: | 4 |
Range: | 1-99 |
Usage: | Minimum time that silence must be present to produce a T_SILON or T_SILOFF CST event. |
Parameter: | TTDATA |
Description: | Duration of dialed DTMF tones in 1/100 seconds. |
Default: | 10 |
Range: | 1-99 |
Usage: | Duration of the DTMF digits in out-bound tone dialing. |
Parameter: | MINPDON |
Description: | Minimum make interval for valid loop pulse digit in 1/100 seconds |
Default: | 2 |
Range: | 1-9 |
Usage: | Minimum make interval to validate an incoming loop pulse digit. |
Parameter: | MINPDOFF |
Description: | Minimum break interval for valid loop pulse digit in 1/100 seconds. |
Default: | 2 |
Range: | 1-99 |
Usage: | Minimum break interval to validate an incoming loop pulse digit. |
Parameter: | MINIPD |
Description: | Minimum inter-digit pulse time in 1/100 seconds. |
Default: | 25 |
Range: | 1-99 |
Usage: | Minimum time between loop pulse digits. |
Parameter: | MINLCOFF |
Description: | Minimum time for loop current drop detect in 1/100 seconds |
Default: | 30 |
Range: | 1-99 |
Usage: | Minimum time that loop current must be off for Dialogic to report a loop current drop. |
Parameter: | REDGE |
Description: | Detect Ring signal on rising edge |
Default: | No |
Range: | Yes/No |
Usage: | Specifies whether a ring is detected on the leading or trailing edge. Trailing edge is needed in a T1 environment. |
Parameter: | MAXPDOFF |
Description: | Maximum time for pd make in 1/100 seconds. |
Default: | 50 |
Range: | 1-99 |
Usage: | Maximum make interval to validate an incoming loop pulse digit. |
Parameter: | CST_MASK |
Description: | CST mask for Dialogic driver events |
Default: | 17 |
Range: | 1-99 |
Usage: | Current call status mask as set by the SETCST( ) function. |