To view/change Dialogic Parameters, select CALLMaster Manager | Parameters | Dialogic.
Dialogic Parameters 20 thru 38
Parameter: | LOGLTCH |
Description: | Time above which silence interval is noise spike |
Default: | 15 |
Range: | 1-99 units (10ms per unit) |
Usage: | The maximum silence period to ignore. Used to help eliminate spurious silence intervals. Sometimes used to improve pager notification - try a value between 6 and 12. |
Parameter: | HIGLTCH |
Description: | Time below which silence interval is noise spike |
Default: | 19 |
Range: | 1-99 units (10ms per unit) |
Usage: | The maximum nonsilence period to ignore. Used to help eliminate spurious nonsilence intervals. Sometimes used to improve pager notification - try a value between 6 and 12. |
Parameter: | LO1RMAX |
Description: | Maximum time of short low interval ring |
Default: | 90 |
Range: | 1-999 |
Usage: | Maximum short low duration of double ring. |
Parameter: | LO2RMIN |
Description: | Minimum time of long low interval ring |
Default: | 225 |
Range: | 1-999 |
Usage: | Minimum long low duration of double ring. |
Parameter: | INTFLG |
Description: | Operator intercept detection enable |
Default: | 1 |
Range: | 1-8 |
Usage: | This parameter enables or disables SIT Detection, Positive Voice Detection, and Positive Answering Machine Detection, and selects the mode of operation for SIT Detection. The definitions below are followed by a table summarizing the features and options. 1 - OPTEN: Enable SIT Detection and wait for detection of a connect using Cadence Detection, Loop Current Detection, Positive Voice Detection, or Positive Answering Machine Detection before returning a CA_OPINT (operator intercept). 2- OPTDIS: Disable SIT Detection, PVD and PAMD. 3 - OPTCON: Enable SIT Detection; return a CA_OPINT (operator intercept) immediately after detecting a valid frequency. (This is the recommended mode for SIT detection.) 4 - PVD_ENABLE:Enable PVD. 5 - PVD_OPTEN: Enable PVD and OPTEN. 6 - PVD_OPTCON: Enable PVD and OPTCON. 7 - PAMD_ENABLE: Enable PAMD and PVD. 8 - PAMD_OPTEN: Enable PAMD, PVD, and OPTEN. Note: If you want to enable the answer size capability, you must use PVD_ENABLE, PVD_OPTEN, or PVD_OPTCON for PVD_ENABLE, PVD_OPTEN, or PVD_OPTCON for basic Call Progress Analysis; otherwise, a salutation answer size will not be provided. (You must also set the HEDGE and ANSRDGL fields to enable answer size capability.) |
Parameter: | INTFLTR |
Description: | Minimum intercept tone duration for detection |
Default: | 10 |
Range: | 1-99 |
Usage: | The minimum duration of the intercept tone in order for it to be detected. |
Parameter: | HISIZ |
Description: | Used in comparison with previous hi |
Default: | 90 |
Range: | 1-99 |
Usage: | Used to determine whether to use ALOWMAX or BLOWMAX. |
Parameter: | ALOWMAX |
Description: | If previous hi > HISIZ use this value |
Default: | 700 |
Range: | 1-999 |
Usage: | Maximum low before connect if high > HISIZ. |
Parameter: | BLOWMAX |
Description: | If previous hi < HISIZ use this value |
Default: | 530 |
Range: | 1-999 |
Usage: | Maximum low before connect if high < HISIZ. |
Parameter: | NBRBEG |
Description: | Ring on which to begin analysis |
Default: | 1 |
Range: | 1-9 |
Usage: | Number of nonsilence periods before analysis begins. |
Parameter: | HI1CEIL |
Description: | If 1st hi < 2nd hi |
Default: | 78 |
Range: | 1-99 |
Usage: | Maximum 2nd high duration for a retrain. |
Parameter: | LO1CEIL |
Description: | The 1st learned LO is less than this |
Default: | 58 |
Range: | 1-99 |
Usage: | Maximum 1st low duration for a retrain. |
Parameter: | LOWERFRQ |
Description: | Lower allowable frequency in Hertz of a SIT tone |
Default: | 900 |
Range: | 1-9999 (in Hz) |
Usage: | Lower bound for 1st tone in an SIT. |
Parameter: | UPPERFRQ |
Description: | Upper allowable frequency in Hertz of a SIT tone |
Default: | 1000 |
Range: | 1-9999 (in Hz) |
Usage: | Upper bound for 1st tone in an SIT. |
Parameter: | TIMEFRQ |
Description: | Minimum duration of signal for operator intercept in 1/100 seconds |
Default: | 5 |
Range: | 1-99 |
Usage: | Minimum time for 1st tone in an SIT to remain in between CPB UPPERFRQ and LOWERFRQ for it to be considered valid. |
Parameter: | REJCTFRQ |
Description: | Maximum allowable percent of bad signal |
Default: | 20 |
Range: | 1-99 |
Usage: | Maximum allowable percent of a bad signal. |
Parameter: | MAXANSR |
Description: | Maximum duration of answer in 1/100 seconds |
Default: | 1000 |
Range: | 1-9999 |
Usage: | The maximum allowable length of ANSRSIZE. When ANSRSIZE exceeds MAXANSR, a connect is returned to the CALLMaster. |
Parameter: | ANSRDGL |
Description: | Silence deglitching value for answer |
Default: | -1 |
Range: | 1-99, -1 |
Usage: | The maximum silence period allowed between words in a salutation. If Positive Voice Detection (PVD) is enabled and you want to enable the answer size capability, you must also enable ANSRDGL (default is disabled) by setting it to a value other than -1. The ANSRDGL parameter should be enabled only when you are interested in measuring the length of the answer. This function is disabled by setting the field to -1 (the default). |
Parameter: | MXTIMEFRQ |
Description: | Maxtime for 1st Freq |
Default: | 0 |
Range: | 0-1000 10 ms |
Usage: | Maximum time for 1st tone in a SIT. |