To view/change Dialogic Parameters, select CALLMaster Manager | Parameters | Dialogic.
Dialogic Parameters 39 thru 57
Parameter: | LOWER2FRQ |
Description: | Lower 2nd Freq |
Default: | 0 |
Range: | 0-3000 HZ |
Usage: | Lower bound for 2nd tone in a SIT. |
Parameter: | UPPER2FRQ |
Description: | Upper 2nd Freq |
Default: | 0 |
Range: | 0-3000 HZ |
Usage: | Upper bound for 2nd tone in a SIT. |
Parameter: | TIME2FRQ |
Description: | Min Freq Time |
Default: | 0 |
Range: | 0-1000 10ms |
Usage: | Minimum time for 2nd tone freq to remain in bounds. |
Parameter: | MXTIME2FRQ |
Description: | Maxtime for 2nd Freq |
Default: | 0 |
Range: | 0-1000 10 ms |
Usage: | Maximum time for 2nd tone in a SIT. |
Parameter: | LOWER3FRQ |
Description: | Lower 3rd Freq |
Default: | 0 |
Range: | 0-3000 HZ |
Usage: | Lower bound for 3rd tone in a SIT. |
Parameter: | UPPER3FRQ |
Description: | Upper 3rd Freq |
Default: | 0 |
Range: | 0-3000 HZ |
Usage: | Upper bound for 3rd tone in a SIT. |
Parameter: | TIME3FRQ |
Description: | Min Freq 3 Time |
Default: | 0 |
Range: | 0-1000 10ms |
Usage: | Minimum time for 3rd tone freq to remain in bounds. |
Parameter: | MXTIME3FRQ |
Description: | Maxtime for 3rd Freq |
Default: | 0 |
Range: | 0-1000 10 ms |
Usage: | Maximum time for 3rd tone in a SIT. |
Parameter: | DTNPRES |
Description: | Dial Tone Present |
Default: | 100 |
Range: | 0-1000 10 ms |
Usage: | Length of time a Dial Tone must be continuously present. |
Parameter: | DTNNPRES |
Description: | Dial Tone Not Present |
Default: | 300 |
Range: | 0-1000 10 ms |
Usage: | Maximum length of time to wait before declaring Dial Tone not present. |
Parameter: | DTNDEBOFF |
Description: | Dial Tone Debounce Off |
Default: | 10 |
Range: | 0-1000 10 ms |
Usage: | Maximum gap in dial tone to be considered continuous. |
Parameter: | PAMFAILTIME |
Description: | Positive Answering Machine fail time |
Default: | 400 |
Range: | 0-1000 10 ms |
Usage: | Length of time to wait for PAM detection or Positive Voice Detection before declaring failure i.e. no answer. |
Parameter: | PAMMINRING |
Description: | Positive Answering Machine minimum ring time duration |
Default: | 190 |
Range: | 0-1000 10 ms |
Usage: | Minimum length of time to wait for ring for PAM detection. |
Parameter: | PAMDSPVAL |
Description: | Positive Answering Machine detection type |
Default: | 3 |
Range: | 1,2,3 |
Usage: | 1 – Full, 2-quick, 3- accurate evaluation for PAMD |
Parameter: | PAMDQTEMP |
Description: | Positive Answering Machine Detection Template # |
Default: | 11 |
Range: | 11,12 |
Usage: | 11- Only Template valid at this time. |
Parameter: | NOANSWER |
Description: | Positive Answering Machine no answer |
Default: | 3000 |
Range: | 0-10000 10 ms |
Usage: | Length of time to wait after first ring for PAM detection before deciding no answer. |
Parameter: | MAXINTERING |
Description: | InterRing Maximum time |
Default: | 800 |
Range: | 0-1000 10 ms |
Usage: | Maximum time to wait between ring back before deciding a disconnect. |
Parameter: | FLASH_CHAR |
Description: | Character in dialing string denoting a flash-hook |
Default: | & |
Range: | ASCII characters |
Usage: | Character in the dialing string that causes a flash-hook to occur. The ASCII character ‘&’ is represented by the number 38. |
Parameter: | FLASH_TIME |
Description: | Flash on-hook duration in increments of 1/100 seconds. |
Default: | 50 |
Range: | 1-99 units (10ms per unit) |
Usage: | Length of time on hook during a hook flash. |